Customized Products
450℉/232℃ EPDM/LEAD Flat Electrical Submersible Pump Cable
Application:
These cables are designed for transmitting power to the submersible motor in the oil industry, suitable for installed down well in the oil industry.
Standard:
IEEE Std. 1018 API RP 11S5 API RP 11S6
Construction :
Conductor: Solid bare copper conductor.
Insulation: EPDM insulation with a poly adhesive layer to the conductor.
Jacket: Lead jacket.
Tape: Overlapped fiber cloth bedding tape.
Armor: Galvanized steel tape.
Capillary Tube: SS 316.
Dimensions and Weight:
5KV
Cable Type | Conductor Size |
Conductor O.D. |
Insulation Thickness |
Overall O.D. | Weight | |||
---|---|---|---|---|---|---|---|---|
AWG | mm² | mm | Inches | mm | Inches | mm | kg/km | |
QYEQC-232-5KV-3G2 |
2 |
33.62 |
6.54±0.07 |
0.07 |
1.9 |
0.63 x 2.40 |
16.0 x 61.0 |
3820 |
QYEQC-232-5KV-3G4 |
4 |
21.15 |
5.19±0.05 |
0.07 |
1.9 |
0.57 x 2.24 |
14.5 x 57.0 |
3240 |
Electrical Data:
Voltage | KV AC |
5 |
---|---|---|
Minimum Insulation Resistance (15.6℃) | MΩ·km |
2AWG-1294; 4AWG-1548 |
Maximum DC Current Unbalance | % |
2 |
Maximum DC Leakage (15.6℃) | μA/(KV·km) |
2AWG-0.77; 4AWG-0.65 |
Maximum DC Conductor Resistant | Ω/km |
2AWG-0.522; 4AWG-0.83 |
DC 35kV/5min |
|
No breakdown |
Mechanical Data:
Temperature Rated | ℃ |
232 |
---|---|---|
Minimum Bending Radius | mm |
2AWG-320; 4AWG-280 |