HOMEPRODUCTSCUSTOMIZED CABLES

 

Customized Products

450℉/232℃ EPDM/LEAD Flat Electrical Submersible Pump Cable

 


Application

These cables are designed for transmitting power to the submersible motor in the oil industry, suitable for installed down well in the oil industry.

Standard

IEEE Std. 1018 API RP 11S5 API RP 11S6

Construction

450℉/232℃ EPDM/LEAD Flat Electrical Submersible Pump Cable

Conductor: Solid bare copper conductor.

Insulation: EPDM insulation with a poly adhesive layer to the conductor.

Jacket: Lead jacket.

Tape: Overlapped fiber cloth bedding tape.

Armor: Galvanized steel tape.

Capillary Tube: SS 316.

Dimensions and Weight

5KV

Cable Type Conductor
Size
Conductor
O.D.
Insulation
Thickness
Overall O.D. Weight
  AWG mm² mm Inches mm Inches mm kg/km

QYEQC-232-5KV-3G2

2

33.62

6.54±0.07

0.07

1.9

0.63 x 2.40

16.0 x 61.0

3820

QYEQC-232-5KV-3G4

4

21.15

5.19±0.05

0.07

1.9

0.57 x 2.24

14.5 x 57.0

3240

Electrical Data

Voltage

KV AC

5

Minimum Insulation Resistance (15.6℃)

MΩ·km

2AWG-1294; 4AWG-1548

Maximum DC Current Unbalance

%

2

Maximum DC Leakage (15.6℃)

μA/(KV·km)

2AWG-0.77; 4AWG-0.65

Maximum DC Conductor Resistant

Ω/km

2AWG-0.522; 4AWG-0.83

DC 35kV/5min

 

No breakdown

Mechanical Data

Temperature Rated

232

Minimum Bending Radius

mm

2AWG-320; 4AWG-280